Joes Gone STEEL

Why Choose Us

All what You Need To Know About Us

Joes Gone STEEL Co., Ltd. is a company specialized in mild steel plate,shipbuilding steel plate,Boiler steel,Weathering steel plateThe supply capacity per year is about 8,900,000 tons steel plate/coil according to EN10025,EN10028,ASTM A36,ASTM A131, JIS G3101,JIS G3106...

  • Gas cylinder steel plate

    Gas cylinder steel plate

    Gas cylinder steel plate is used in welded gas cylinder and related products. supplies gas cylinder steel with better anti-stress capability. Popular......

    More
  • Shipbuilding steel plate

    Shipbuilding steel plate

    shipbuilding steel plate suppliers,we supply A,B,D,E,AH32,DH32,EH32,FH32,AH36,DH36,EH36,FH36,AH40,DH40,EH40,FH40 with ABS,DNV,GL ....

    More
  • Boiler pressure vessel steel

    Boiler pressure vessel steel

    Boiler and pressure vessel grade steel comes in a variety of grades and thicknesses, and are designed to withstand the immense internal ......

    More
  • Alloy steel Plate

    Alloy steel Plate...

    Alloy steel is steel that is alloyed with a variety of elements in total amounts between 1.0% and 50% by weight to improve its mechanical properties. ...

    More
  • Q345B steel plate

    Q345B steel plate

    Steel grade Q345B is the most common used as high strength low alloy structural steel in industry area. ...

    More
  • Q235B steel plate

    Q235B steel plate

    Q235 steel is Chinese structural steel, Q235A Q235B Q235C Q235D material density: 7.85 g/cm3, properties, specification, composition .. ..

    More

Quick Message

Fill in this form or click the service online, all questions will be answered.

cl2 stel

  • Chlorine CDC

    Dec 04, 2014 · *NoteConversion factor (CF) was determined with "n" = 3.5 [ten Berge et al. 1986]. Other animal dataRD 50 (mouse), 9.34 ppm [Alarie 1981]. Other human dataExposures to 30 ppm have been reported to cause intense coughing fits and exposure to 40 to 60 ppm for 30 to 60 minutes or more may cause serious damage [ILO 1971]. A concentration of 34 to 51 ppm has been reported to be lethal in 1 Read More

  • Chlorine Gas Exposure Limits

    STEL Short Term Exposure Level The employees 15 minute time weighted average which should not be exceeded at any time during the work day. In some cases a STEL of another time limit (e. g. STEL (30)) may be specified. TLV * Threshold Limit Value, as defined by ACGIHRead More

  • 1988 OSHA PEL Project Chlorine NIOSH CDC

    Sep 28, 2011 · In 1986, the ACGIH proposed revising the TLVs for chlorine to 0.5 ppm as an 8 hour TWA and 1 ppm as a 15 minute STEL. This proposal was based on a review of two recent studies. One study, a 1981 doctoral dissertation by Anglen (Ex. 108A), was sponsored by the Chlorine Institute and was conducted on 29 human subjects.Read More

  • 442 Threshold Limit Values (TLV) and Immediately

    Substance TWA STEL IDLH TLV TLV Substance TWA STEL IDLH Acetaldehyde 25C 2,000 Acetic Acid 10 15 50 Acetone 500 750 2,500 Acetonitirle 20 500 Acrolein 0.1C 2 Acrylonitrile 2 85 Ammonia 25 35 300 Arsine 0.05 3 Benzene 0.5 2.5 500 Boron Trifluoride 1C 25 Bromine 0.1 0.2 3 1,3 Butadiene 2 2,000 Butane 1,000 Read More

  • OSHA Occupational Chemical Database Occupational

    This chemical inventory is OSHA's premier one stop shop for occupational chemical information. It compiles information from several government agencies and organizations. Information available on the pages includesChemical identification and physical properties Exposure limits Sampling information Read More

  • Method NumberID 101 Occupational Safety and

    5.2.3 Sample at a flow rate of 1 L/min. For STEL determinations, a minimum sampling time of 15 min is recommended. 5.2.4 For measurements of TWA exposures, sample up to 240 min. Take enough samples to cover the shift worked. 5.2.5 Transfer the collection solution into a 20 mL glass scintillation vial. Rinse the bubbler withRead More

  • Health Hazards The Chlorine Institute

    Health Hazards. Chlorine gas is primarily a respiratory irritant. At low concentrations, chlorine gas has an odor similar to household bleach. As the concentrations increase from the level of detection by smell, so do the symptoms in the exposed individual.Read More

  • SAFETY DATA SHEET Airgas

    Chlorine Section 8. Exposure controls/personal protection chlorine ACGIH TLV (United States, 3/2016). STEL2.9 mg/m³ 15 minutes. STEL1 ppm 15 minutes.Read More

  • TLV &reg Chemical Substances Introduction

    Policy Statement on The Uses of TLVs® and BEIs®
  • Toxic gas exposure limits and alarm levels Crowcon

    STEL (15 minute TWA) PPMLTEL (8hr TWA) PPMAmmonia NH 3 25 35 50Arsine A s H 3 0.05 0.05Bromine Br 2 0.1 0.2 0.1Carbon Dioxide CO 2 5000 15000 5000Carbon Monoxide CO 20 100 50Chlorine Cl 2 0.5 1 ceiling * Chlorine Dioxide ClO 2 0.1 0.3 0.1Diborane B 2 H 6 0.1 0.1Ethylene Oxide ETO C 2 H 4 0 5 1Fluorine F 2 1 1Read More

  • Selection of stainless steels for handling chlorine (Cl2

    Selection of stainless steels for handling chlorine (Cl2) and chlorine dioxide (ClO2) Introduction. Chlorine is a powerful oxidising agent. It normally occurs as a gas but can be liquefied under pressure at ambient temperatures.Read More

  • 2015 Exposure Limits for Hydrogen Chloride (HCl)

    Inhaling hydrogen chloride gas or hydrochloric acid mist can cause harmful health effects, such as hyperplasia of laryngeal tissues. Hyperplasia is a chronic effect that arises with repeated exposure over time and is an abnormal increase in the number of non cancerous cells. Hyperplasia can cause:Read More

  • Chlorine Gas Safety Data Sheet SDS P4580

    Formula Cl2 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture Industrial use. Use as directed. 1.3. Details of the supplier of the safety data sheet Praxair, Inc. 10 Riverview Drive Danbury, CT 06810 6268 USA T 1 800 772 9247 (1 800 PRAXAIR) F 1 716 879 2146 praxair 1.4.Read More

  • CL2 Chlorine Globeinstrument

    Chlorine(CL) is a toxic gas greenish yellow gas with a characteristic odour. Chlorine combines directly with nearly all elements. Chlorine is a respiratory irritant. CL irritates the mucous membranes and the liquid burns the skin. CL is detectable in concentrations of Read More

  • MATERIAL SAFETY DATA SHEET Matheson

    ACGIH TLV OSHA STEL NIOSH RELs NIOSH OTHER TWA STEL TWA STEL TWA STEL IDLH CHEMICAL NAME CAS # mole % ppm ppm ppm ppm ppm ppm ppm ppm Chlorine 7782 50 5 1 < 5.86 0.5 1 0.5 (Vacated 1989 PEL) 1 (ceiling) NE 0.5 (ceiling) 15 min. 10 DFG MAKsTWA = 0.5 PEAK = 1MAK 15 min., average value, 1 hr interval, 1 (ceiling) DFG MAK PregnancyRead More

  • What are TWA, PEL and REL? Enviromed Detection Services

    QWhat are TWA, PEL and REL? AThe Threshold Limit Value (TLV (R) ) of a chemical substance establishes the reasonable level to which a worker may be repeatedly exposed, day after day, over a working lifetime without adverse health effects.TLV (R) is a reserved term of the American Conference of Governmental Industrial Hygienists (ACGIH) (R) .It is however sometimes loosely used to refer to Read More

  • ToxiRAE Pro Users Guide RAE Systems

    ToxiRAE Pro Users Guide 6 1. General Information ToxiRAE Pro is a personal wireless monitor for toxic gases and oxygen deficiency/enrichment. The ToxiRAE Pro can detect a broad range of gasesfrom carbon monoxide, hydrogen sulfide, and oxygen to ammonia, chlorine, and phosgene.Read More

  • MATERIAL SAFETY DATA SHEET KOH Chlorine CL2

    material safety data sheet ASHTA Chemicals Inc. P.O. Box 858 Ashtabula, OH 44004 (440) 997 5221 CHLORINE LIQUIDRead More

  • Gas Detector Alarm Settings General Gas Education

    Notea. For CO, OSHA PEL is 50 ppm, Industrial Scientific uses the standard set in 1989 (35 ppm). All alarm set points are field adjustable over the full range of the sensor, exceptionsLEL/CH4 0 to 60% and 0 to 3.0% by vol CH4.Read More

  • DATE OF EFFECT18 April 2013 Safe Work Australia

    The STEL is a 15 minute time weighted average (TWA) exposure limit which must not be exceeded at any time during an 8 hour working day, even if the exposure during the full day is less than the eight hour TWA exposure standard. Exposures at the STEL must not be longer than 15Read More

  • orine sensors GG CL2 B CHLORINE SENSOR

    Accurately monitor OSHAs PEL, STEL, and IDLH setpoints Detection range of 0 5 ppm Cl2 GG CL2 B CHLORINE SENSOR The GG CL2 B utilizes proven electro chemical sensor technology for fast and accurate detection. The standard detection range of the GG CL2 B pro vides real time continuous monitoring of chlorine concentrations accuratelyRead More

  • What are H2S Exposure Limits? Definition from Safeopedia

    OSHA Permissible Exposure Limits (PEL) for H2S are listed below for conditions statedGeneral industry up to 20 ppm. Exceptions may exceed 20 ppm if no other exposures during 8 hour work shift, but not more than 50 ppm for a single time exposure for 10 minutes.Read More

  • Where should I set the alarms on Interscan Corporation

    Cal/OSHA has a draft proposal touting a 15 minute STEL of 0.4 ppm, and an 8 hour PEL of 0.15ppm. NIOSH set a draft IDLH of 0.64 ppm (1.7 mg/m 3) in 2015, which met with considerable resistance. ACGIH does have a published TLV STEL of 0.4 ppm. Given the ACGIH value, one might consider an alarm 1 of 0.4 ppm, and an alarm 2 of 1.5 ppm.Read More

Quick Message

Fill in this form or click the service online, all questions will be answered.

Quick Message

Fill in this form or click the service online, all questions will be answered.